Huawei eKit Switch 48x1000Mbps + 4x1GE (SFP) + 1konzol port, iStack, Rackes, Layer2+ managed - S310-48T4S 98012203
First supported version
V600R022C10
Integrated fixed device
Y
Dimensions without packaging (H x W x D) [mm(in.)]
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)
Dimensions with packaging (H x W x D) [mm(in.)]
90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.)
Chassis height [U]
1
Installation type
Rack mounting,Desk mounting,Wall mounting
Weight without packaging [kg(lb)]
2.71 (5.97)
Weight with packaging [kg(lb)]
3.59 (7.91)
Typical power consumption [W]
44.9
Typical heat dissipation [BTU/hour]
153.2
Maximum power consumption [W]
52.05
Maximum heat dissipation [BTU/hour]
177.6
Static power consumption [W]
27.55
100% power consumption [W]
45.66
MTBF [year]
40.61
MTTR [hour]
2
Availability
>0.99999
Noise at normal temperature (acoustic power) [dB(A)]
46.6
Noise at high temperature (acoustic power) [dB(A)]
54.3
Noise at normal temperature (acoustic pressure) [dB(A)]
34.6
Number of card slots
0
Number of power slots
0
Number of fans modules
1
Maximum number of physical ports on the entire device
52
Maximum number of 100GE ports
0
Maximum number of 40GE ports
0
Maximum number of 25GE ports
0
Maximum number of 10GE ports
0
Maximum number of 5GE ports
0
Maximum number of 2.5GE ports
0
Maximum number of GE ports
52
Maximum number of FE ports
48
Dedicated stack port
Not supported
Redundant power supply
Not supported
Long-term operating temperature [°C(°F)]
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
Restriction on the operating temperature variation rate [°C(°F)]
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). The operating temperature ranges from –5°C (23°F) to +45°C (113°F) when optical modules with transmission distances greater than or equal to 60 km are used.
Storage temperature [°C(°F)]
–40°C to +70°C (–40°F to +158°F)
Long-term operating relative humidity [RH]
5% RH to 95% RH (non-condensing)
Long-term operating altitude [m(ft.)]
0–5000 m (0–16404 ft.)
Storage altitude [m(ft.)]
0-5000 m (0-16404 ft.)
Power supply mode
AC built-in
Rated input voltage [V]
AC input: 100–240 V AC; 50/60 Hz
Input voltage range [V]
AC input: 90–290 V AC; 45–65 Hz
Maximum input current [A]
1.6 A
CPU
1.1 GHz, 2 cores
Memory
2 GB
Flash memory
1 GB in total. To view the available flash memory size, run the display version command.
Console port
RJ45
Eth Management port
Not supported
USB
Not supported
Hardware real-time power detection
Not supported
Dying gasp
Supported
RTC
Not supported
RPS input
Not supported
Complete device sleeping
Not supported
Service port surge protection [kV]
Common mode: ±7 kV
Power supply surge protection [kV]
Differential mode: ±6 kV; common mode: ±6 kV
Ingress protection level (dustproof/waterproof)
IP20
Types of fans
Built-in
Heat dissipation mode
Air cooling for heat dissipation, intelligent fan speed adjustment
Airflow direction
Air intake from left and air exhaust from right
PoE
Not supported
Maximum PoE power consumption [W]
-
PoE+ power interfaces
-
PoE++ power interfaces
-
Full load PoE power consumption 15.4W (802.3af)
-
Full load PoE power consumption 30W (802.3at)
-
Full load PoE++ power consumption 60W (802.3bt)
-
Full load PoE++ power consumption 90W (802.3bt)
-
Certification
EMC certification Safety certification Manufacturing certification
| Raktárkészlet | 1-2 munkanap |
| Lagerbestand | 1-2 munkanap |
| Starea stocului | 1-2 munkanap |
| Stock status | 1-2 munkanap |
| Állapot | Új |
| Bedingung | Új |
| Condiție | Új |
| Condition | Új |